Vacuum Elevator PVE52 Philippines

Wheelchair accessible home lift

 
 

Vacuum Elevator PVE52

The pneumatic vacuum elevator PVE52 model is specially designed for people with reduced mobility. This model pneumatic vacuum elevator allows the possibility of transporting a passenger in a wheelchair.

The Vacuum Elevator PVE52 in the Philippines features an exterior diameter of 1.36 m, comfortably accommodating up to three people (238 kg). This model is available as a Vacuum Elevator PVE52 Home Wheelchair Lift and comes in configurations of two, three, and four stops, reaching a maximum height of 10.5 meters. The PVE52 Home Elevators and Residential Elevators are perfect for those seeking a spacious and panoramic solution for their homes, offering both functionality and style.

There are many wheelchair home lifts, but only our pneumatic vacuum elevator PVE52 gives you the space and security you need with a spectacular design. The exterior cylinder of the biggest of our vacuum elevators is made of aluminum and transparent polycarbonate. It is also the only model with stainless steel interior cabin. A perfect finish!

The vacuum elevator greatly reduces energy costs and maintenance, as our pneumatic vacuum elevator works without pulleys or pistons. This allows for low energy consumption during ascent and zero during descent. The pneumatic vacuum elevators are eco friendly elevators.

The Vacuum Elevator PVE52 is designed to provide a seamless and efficient lifting experience in your home. For those interested, the Vacuum Elevator PVE52 manual is available to guide you through its features and installation. You can find the Vacuum Elevator PVE52 for sale at various authorized dealers, ensuring you get a reliable product. Our service is top-notch, with no problems reported by our customers, making it a perfect choice for a smooth and stylish home lift experience.

General:

  • External cylinder diameter: 52 11/16” (1,316mm)

  • Rated Load: 525 lbs. (238 kg)

  • Speed: 20 fpm (.10 ms)

  • No pit required. Bottom level floor must be 100% level as elevator rests on existing floor.

  • No hoistway required.

Minimum overhead clearance:

  • Standard Unit (turbine motors located on top): 107” (2,719mm)

  • Split Unit (turbine motors located remotely): 97” (2,464mm)

  • Penetration required to install through floors and ceilings: 54 11/16” (1,389mm)

Mechanical Requirements:

  • 220V, 60/50 Hz, 35amp single phase power supply

  • 6 turbine motors located in pump box using a total of 6KW

Cabin:

  • Entrance width opening: 32” (813mm)

  • Internal cabin height: 79” (2007mm)

  • Internal cabin diameter: 44” (1,118mm)

  • Automatic LED lighting and cabin fan

  • Door openings: same side (in-line) and walk through (180º).

  • All doors are hinged on top left, with door swing to the left, from inside the cabin.

  • Door Height: 79 . ” (2,026mm)

  • Height to top of Door closer: 81 .” ( 2,071mm)

  • Each landing level specified will include only one door.

  • 24 Volt electrical circuits with all controls in cabin

  • Push button call controls with precise leveling at each landing.

  • Telephone

Safety:

  • Automatic descent to ground level at safety speed in the event of a power failure.

  • Mechanical emergency brakes within two inches of freefall in vacuum loss or catastrophic failure.

  • Electromechanical interlocks at each landing

Standard Model

  • Minimum height required at the ground floor is 92” (2,34 m).

  • Minimum required height at the upper floor is 107” (2,70 m).

  • Diameter of finished through floor hole must be 5411/16” (1,46m).

  • When installing a three or four floor elevator, all openings circular perforations should be perfectly aligned.

  • The electric feed shall be 220VAC single phase through an independent line of conductors of AWG N° 10 (6mm ); there shall be ground connection and a thermo-magnetic switch of 35A to be used exclusively for the elevator. The electrical supply is to be near the head (elevator’s top portion) and it is required to leave the female electrical receptacle at the top center of the elevator.

  • 220VAC (no exceptions 220VAC must be provided, 210VAC or 230VAC is not acceptable, if installation does not have 220VAC on a regular basis, a voltage regulator or transformer must be installed by home owner). Voltage fluctuations are not covere by the warranty.

  • If installing a phone line a phone jack is to be provided near the power supply, but isolated.

  • It is strongly recommended that a Buck Boost or voltage stabilizer be installed along with the electrical work to prevent any damage to electrical components due to voltage fluctuation.

  • When installing the elevator, consider the total dimensions, as a small room will generate a higher noise level. Therefore, it is not advisable to install the split motor in a very small facility.

  • There must be an opening to make way for the cylinders of 54 11/16” (1,39 m) in diameter and of 92” (2,34 m) in length down to the ground floor. This access may be through door or window openings.

  • Install a hook to bear 800kg at the ceiling where the elevator is to be installed to lift the cylinders. If it is impossible to install this hook, the minimum height at the last level shall be at least 109” (2,75 m).

  • In no case must the perforation of the ceiling be less than 2” (5cm) from the wall, in order to allow for the installation tripod.

Split Unit Model

All requirements for the split unit model (remote location of head unit) are the same as the standard model except for the following…

  • Minimum required height at the upper floor is 97” (2,47 m).

  • Required space for remote location of head unit in attic or adjacent closet is 39” L x 25” W x 26” H (0,84m x 0,45m x 0,68m)

  • Remote location of head unit can be accommodated up to 30 linear feet (10 m) away from the elevator.

  • Split unit connections require two 4” (10cm) PVC pipes to run the distance from the top of the upper floor cylinder split plate to the remote location of the head unit.

  • Air supply to split unit has to be drawn from interior of residence (proper housing of head unit and air duct to interior of home required)

  • Electrical power supply to be provided within direct access to remote location of head unit.

Download Catalogue

Download all the information

Want a quote?

Please submit your quote form

If you are looking for additional information or to find the contact information of your local dealer, please fill out our quick contact

 

Gallery

Installations PVE52 model

Would you like to learn more?

Request a quote without compromise

Contact us and tell us which pneumatic elevator model is best for your size or functionality and how many stops / doors you need. Our commercial technical team will be happy to help you.